- Clone:
- REAL104
- Type of antibody:
- Releasable antibodies, Primary antibodies, Recombinant antibodies
- Applications:
- FC Glossary
- Select a conjugate:
- Select a size:
Related products for CD3 Antibody, anti-human, REAlease®
In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.
Cells were incubated with an excess of purified unconjugated CD3 (REAL104) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.
To ensure antibody specificity, the target gene is knocked out in a suitable cell line using the CRISPR/Cas9 system and the knockout is confirmed by sequencing of the target locus. The antibody is considered to bind specifically to the intended epitope if no antibody binding to the knockout cells can be detected. The antibody staining is controlled by fluorescence microscopy and/or flow cytometry.
Fluorescence microscopy image of CD3 knockout cells. Wild type (WT, left) and knockout cells (KO, right) were stained with CD3-PE (REAL104, red) and counterstained with DRAQ5 (blue) as DNA stain.
Overlay histogram showing flow cytometric analysis of human CD3 knockout cells. Wild type (red) and knockout cells (blue) were stained with CD3-PE, clone (REAL104). Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells and cell doublets were excluded from the analysis based on scatter signals and propidium iodide fluorescence.
Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.
Flow cytometric comparison of different clones for CD3. Human peripheral blood mononuclear cells (PBMCs) were stained with CD3 antibodies and with a suitable counterstaining. As a control, CD3 antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.
To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.
Comparison of staining pattern on non-fixed and fixed cells using CD3 (REAL104). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.
Clone REAL104 is an antibody fragment derived from the full CD3 antibody molecule. It displays no binding to Fc receptors. The recombinantly engineered antibody fragments are multimerized to form the REAlease Complex to bind markers with high avidity.
Clone REAL104 recognizes the human CD3 antigen, a single-pass type I membrane protein also known as Leu4. CD3 is present on mature human T cells, thymocytes, a subset of NK cells, and on Purkinje cells in cerebellum. It is associated with the T cell receptor (TCR) and is responsible for its signal transduction. The CD3 antigen is a complex of five invariable chains: γ, δ, ε, ζ, and η. The epitope recognized by clone REAL104 is located on the ε-chain of the CD3 complex.
The REAlease Kits consist of the respective fluorochrome-conjugated REAlease Complexes and the REAlease Support Kit for removal of the REAlease Complexes and optional relabeling with different fluorochrome-conjugated REAlease Complexes.
CD3-epsilon, CD3e, Leu4, T-cell surface antigen T3/Leu-4 epsilon chain, T3E, IMD18, TCRE
Technical specifications
To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.
Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.