CD200 Antibody, anti-rat, REAfinity™
Synonyms: Cspmo2, MRCOX2, Mox2
RECOMBINANT EXTENDED VALIDATION
Clone:
REA532 | OX-2
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD200 Antibody, anti-rat, REAfinity™

Flow cytometry applications
APC
APC-Vio 770
Biotin
FITC
PE
PE-Vio 770
PerCP-Vio 700
Recommended dilution:
1:10
Remark:
Cells should be stained prior to fixation, if formaldehyde is used as a fixative.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-108-127, 130-108-092
Description:
Splenocytes from Wistar rats were stained with CD200 antibodies or with the corresponding REA Control antibodies (left image) as well as with CD45R antibodies. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescence.

Application imageView details view details

Application imageView details view details
Extended validation for CD200 Antibody, anti-rat, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA532
OX-2
high

Cells were incubated with an excess of purified unconjugated CD200 (REA532) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD200. Splenocytes from Wistar rats were stained with CD200 antibodies followed by a suitable counterstain. As a control, CD200 antibody staining was omitted and cells were measured in the same channel. Flow cytometry analysis was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. The recommended titers of respective antibodies from different suppliers were used.

Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD200, shown as histograms. Only positive cells were presented in the image.

Specifications for CD200 Antibody, anti-rat, REAfinity™
Overview

Clone REA532 recognizes the rat CD200 antigen, which is a transmembrane glycoprotein containing two extracellular immunoglobulin domains and lacks intracellular signaling motifs or docking sites for adapter signaling molecules. CD200, also known as MRC OX-2 antigen, is expressed on a variety of tissues, including the nervous system, activated T cells, B cells, dendritic cells in lymphatic follicles, cells of glomeruli and ovarian degenerating follicles, and vascular endothelium. It is also distributed at the epithelium-derived tissues such as the thymus, retinas, and hair follicles. CD200 interacts with CD200R, an immunoglobulin superfamily inhibitory receptor expressed primarily on myeloid/monocyte lineage cells, and has a suppressive effect on T cell–mediated immune response.

Additional information: Clone REA532 displays negligible binding to Fc receptors.

Alternative names

Cspmo2, MRCOX2, Mox2

Detailed product information

Technical specifications

Clone
REA532
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
rat
Antigen
CD200
Molecular mass of antigen [kDa]
28
Distribution of antigen
T cells, B cells, dendritic cells, endothelial cells, ovary
Entrez Gene ID
RRID
AB_2656096, AB_2656098, AB_2656103, AB_2656093, AB_2656105, AB_2656104, AB_2656102, AB_2656100, AB_2656106, AB_2656099, AB_2656097, AB_2656101, AB_2656095, AB_2656094

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD200 Antibody, anti-rat, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

Citations for CD200 Antibody, anti-rat, REAfinity™
Publications
  1. Ya-Fen, J. S. et al. (2010) Distribution and expression of CD200 in the rat respiratory system under normal and endotoxin-induced pathological conditions. J. Anat. 216 (3): 407-416
  2. Barclay, A. N. et al. (1986) Neuronal/lymphoid membrane glycoprotein MRC OX-2 is a member of the immunoglobulin superfamily with a light-chain-like structure. Biochem. Soc. Symp. 51: 149-157
  3. Clark, M. J. et al. (1985) MRC OX-2 antigen: a lymphoid/neuronal membrane glycoprotein with a structure like a single immunoglobulin light chain. EMBO J. 4 (1): 113-118

You have previously chosen International as your location.
What do you want to do?