SARS-CoV-2 T Cell Analysis Kits for human PBMC samples

Analysis of virus-reactive T cells is essential for understanding fundamental immunological processes in infectious diseases such as COVID-19. However, working with these rare cells can prove challenging to researchers.

Our new SARS-CoV-2 T cell Analysis Kits (PBMC), human ensure efficient stimulation and precise analysis of SARS-CoV-2-reactive T cells.

All-in-one kit for the stimulation and analysis of SARS-CoV-2-reactive T cells in human PBMC samples**

The kits include: 

  • With or without a SARS-CoV-2 PepTivator® of choice 
  • An optimized 8-color REAfinity™ Recombinant Antibody Panel (+1 free position)
  • A live/dead marker (Viobility™ 405/452 Fixable Dye)
  • Positive stimulation control (CytoStim™), all required buffers and Brefeldin A
  • Optimized intracellular and extracellular staining panels and protocol
  • Compatible with the MACSQuant® Analyzer for highly efficient analysis

SARS-CoV-2 T Cell Analysis Kit variants 

Without SARS-CoV-2 PepTivator Peptide Pools

SARS-CoV-2 PepTivator Peptide Pools that can be combined with the kit can be found here

Including a SARS-CoV-2 PepTivator Peptide Pool 

  • SARS-CoV-2 Select T Cell Analysis Kit (PBMC), human (#130-128-035)
  • SARS-CoV-2 Prot_S Complete  T Cell Analysis Kit (PBMC), human (#130-128-156)
  • SARS-CoV-2 Prot_S  T Cell Analysis Kit (PBMC), human (#130-127-586)
  • SARS-CoV-2 Prot_S1  T Cell Analysis Kit (PBMC), human (#130-127-585)
  • SARS-CoV-2 Prot_S+  T Cell Analysis Kit (PBMC), human (#130-127-584)
  • SARS-CoV-2 Prot_N  T Cell Analysis Kit (PBMC), human (#130-127-583)

Flow panel included in the SARS-CoV-2 T Cell Analysis Kits (PBMC), human 

A panel of 8 fluorophore-conjugated REAfinity™ Recombinant Antibodies and a live/dead marker (Viobility™ 405/452 Fixable Dye) are included in the kit for precise analysis of SARS-CoV-2-reactive T cells. One channel (PE-Vio®615) is free to allow the addition of one specificity of choice. Additional PE-Vio®615-conjugated specificities may include e.g., IL-2, IL-4, IL-17, CD69, CD137, TIGIT or HLA-DR.

MarkerCloneFluorophore 
CD3REA613 APC 
CD4REA623 Viobright-515 
CD8REA734 VioGreen 
CD154 (CD40L) REA238APC-Vio770 
IFN-g REA600PE 
TNF-a REA656PE-Vio® 770 
CD14REA599VioBlue 
CD20REA780VioBlue 
Live/dead Viobility Fixable Dye 405/452 
Free channel*  PE-Vio® 615 

*For VioDye spectra see here

View details

Analysis of SARS-CoV-2-reactive T cells using the kit 

Human PBMCs from a SARS-CoV-2-reactive donor were incubated for 6 hours with the SARS-CoV-2 PepTivators Select or Prot_S Complete or left unstimulated (negative control). Brefeldin A was added after 2 hours. Cells were then stained with the live/dead marker Viobility 405/452 Fixable Dye, fixed and permeabilized afterwards. Subsequently, cells were stained with the flow panel included in the kit (see table). Cells were analyzed using a MACSQuant Analyzer 16. Doublets, debris, dead cells as well as CD14+ and CD20+ cells were excluded. After pregating on CD3 as well as CD4 and CD8, respectively, activation marker and cytokine expression were assessed, e.g. CD154 and TNF-α for CD4+ T cells and TNF-α and IFN-γ for CD8+ T cells.

Download PDF

Application note
Fast and efficient detection of SARS-CoV-2-reactive T cells via antigen-specific stimulation

If you have further questions don't hesitate to contact us on the form below

Please choose the Kit you are interested in

General Information

Detailed Information

Please give your details for further inquiries.

* Mandatory field

Questions / Comments

Further information on our tools and protocols for virus-specific T cell reseach