CD146 (LSEC) Antibody, anti-mouse, REAfinity™
Synonyms: MCAM, 1-gicerin, CD149, MUC18, S-endo, s-gicerin, Endo-CAM, Mel-CAM
RECOMBINANT EXTENDED VALIDATION
Bioz Star94/100 Bioz rating
8 Citations8 Images
Clone:
REA1064 | ME-9F1
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
FC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for CD146 (LSEC) Antibody, anti-mouse, REAfinity™

Flow cytometry applications
APC
Biotin
FITC
PE
Vio Bright B515
VioBlue
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-118-254, 130-118-408
Description:
Liver cells of C57BL/6 mice were dissociated with the Liver Dissociation Kit, mouse. Cells were then stained with CD146 (LSEC) antibodies or with the corresponding REA Control antibodies (left images) as well as with CD49b antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris and dead cells were excluded from the analysis based on scatter signals and propidium iodide fluorescencer or 4',6-diamidino-2-phenylindole (DAPI) fluorescence, as in the case of tandem conjugates.

Application imageView details view details

Application imageView details view details
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
frozen – PFA
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-140-263
Testing grade:
Fixation:
frozen – Acetone
Species tested:
mouse
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-140-263
Testing grade:
Fixation:
FFPE
Species tested:
mouse
Tissue used:
colon
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-140-263
Testing grade:
Description:
Immunofluorescence analysis of a formalin-fixed, paraffin embedded (FFPE) mouse colon. Before staining, antigens were retrieved using heat-induced epitope retrieval (HIER) at pH 9. The section was stained using CD146 (LSEC) Antibody, anti-mouse, APC (green) for 10 min at room temperature. Nuclei were visualized with Hoechst™ (blue).Scale bar: 30 µm.

Application image
Extended validation for CD146 (LSEC) Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA1064
ME-9F1
high

Cells were incubated with an excess of purified unconjugated CD146 (LSEC) (REA1064) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for CD146 (LSEC). Splenocytes from CD57BL/6 mice were stained with CD146 (LSEC) antibodies and with a suitable counterstaining. As a control, CD146 (LSEC) antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris, dead cells, and cell doublets were excluded from the analysis based on scatter signals and 4',6-diamidino-2-phenylindole (DAPI) fluorescence. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Extended-Validation detailed information image
Fixation data

To provide an indication on how an antibody performs after fixation of cells, in-house data on staining results before and after fixation with 3.7% formaldehyde using Miltenyi Biotec antibodies are provided. Different experimental settings may lead to different results.

No fixation
Extended-Validation detailed information image
Post fixation
Extended-Validation detailed information image

Comparison of staining pattern on non-fixed and fixed cells using CD146 (LSEC) (REA1064). The performance of the antibody after fixation was tested by comparing the staining pattern on fresh (no fixation) versus fixed (post fixation) cells.

Specifications for CD146 (LSEC) Antibody, anti-mouse, REAfinity™
Overview

Clone REA1064 recognizes the mouse CD146 antigen, which is expressed on mouse endothelial cells, including liver sinusoidal endothelial cells (LSECs), smooth muscle cells, and the basal membrane. LSECs are microvascular endothelial cells lining the hepatic sinusoidal wall. Their strategic positioning favors a tight interaction with lymphocytes migrating through the liver. They possess a high capacity for antigen uptake and processing. However, in contrast to professional antigen-presenting cells, e.g. dendritic cells, they express only low levels of costimulatory molecules.

Additional information: Clone REA1064 displays negligible binding to Fc receptors.

Alternative names

MCAM, 1-gicerin, CD149, MUC18, S-endo, s-gicerin, Endo-CAM, Mel-CAM

Detailed product information

Technical specifications

Clone
REA1064
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
CD146 (LSEC)
Molecular mass of antigen [kDa]
69
Distribution of antigen
dendritic cells, endothelial cells, epithelial cells, fibroblasts, stem cells, T cells, ES and iPS cells, mesenchymal stem cells
Entrez Gene ID
RRID
AB_2751509, AB_2751510, AB_2751508, AB_2751475, AB_2751472, AB_2751473, AB_2751506, AB_2751507, AB_2751474, AB_2751511

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for CD146 (LSEC) Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support