Ikaros Antibody, anti-mouse, REAfinity™
Synonyms: Ikaros family zinc finger protein 1, Lyf1, Zfpn1a1, Znfn1a1, Ikzf1
RECOMBINANT EXTENDED VALIDATION
Clone:
REA919 | 2A9/ikaros
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for Ikaros Antibody, anti-mouse, REAfinity™

Intracellular flow cytometry applications
APC
FITC
PE
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-115-275, 130-115-368
Description:
Splenocytes of C57BL/6 were fixed and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Ikaros antibodies or with the corresponding REA Control antibodies (left image) as well as with CD3ε antibodies. Flow cytometry was performed using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application imageView details view details

Application imageView details view details
Extended validation for Ikaros Antibody, anti-mouse, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA919
4E9
low
16B5C71
low
2A9/ikaros
high

Cells were incubated with an excess of purified unconjugated Ikaros (REA919) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Sensitivity
Performance comparison

Selected fluorochrome conjugated antibodies from Miltenyi Biotec were compared to commercially available hybridoma clones in flow cytometry analysis.

Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image
Extended-Validation detailed information image

Flow cytometric comparison of different clones for Ikaros. Splenocytes from C57BL/6 mice were stained with a suitable counterstaining followed by a fixation and permeabilization step using the FoxP3 Staining Buffer Set. Cells were then stained with Ikaros antibodies. As a control, Ikaros antibody staining was omitted and cells were measured in the same channels. Flow cytometry was performed with the MACSQuant® Analyzer. Cell debris and cell doublets were excluded from the analysis based on scatter signals. No FcR Blocking Reagent was used. The recommended titers of respective antibodies from different suppliers were used.

Specifications for Ikaros Antibody, anti-mouse, REAfinity™
Overview

Clone REA919 recognizes the mouse Ikaros protein, also known as DNA-binding protein Ikaros, Ikaros family zinc finger protein 1, or IKZF1. Ikaros is a transcription regulator of hematopoietic cell differentiation of lymphocytes, B cells, and T cells, and functions as a major tumor suppressor involved in human B cell acute lymphoblastic leukemia. In association with other Ikaros-family members, e.g. Aiolos and Helios, Ikaros forms heterodimers, that are important for normal progression to a mature and immunocompetent state. Ikaros is found in the nucleus to a higher extent in granulocytes, B cells, T cells, and NK cells, and in lower levels in erythroblasts, megakaryocytes, and monocytes.

Additional information: Clone REA919 displays negligible binding to Fc receptors.

Alternative names

Ikaros family zinc finger protein 1, Lyf1, Zfpn1a1, Znfn1a1, Ikzf1

Detailed product information

Technical specifications

Clone
REA919
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody, human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
mouse
Antigen
Ikaros
Molecular mass of antigen [kDa]
57
Distribution of antigen
B cells, T cells, megakaryocytes, monocytes, NK cells, granulocytes
Entrez Gene ID
RRID
AB_2727034, AB_2727033, AB_2726976, AB_2726977, AB_2727035, AB_2726978

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for Ikaros Antibody, anti-mouse, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

Citations for Ikaros Antibody, anti-mouse, REAfinity™
Publications
  1. Watkins, N. A. et al. (2009) A HaemAtlas: characterizing gene expression in differentiated human blood cells. Blood 113 (19)
  2. Morgan, B. et al. (1997) Aiolos, a lymphoid restricted transcription factor that interacts with Ikaros to regulate lymphocyte differentiation. EMBO J. 16 (8): 2004-2013
  3. Kastner, P. et al. (2011) Role of Ikaros in T-cell acute lymphoblastic leukemia. J. Biol. Chem. 2 (6): 108-114

You have previously chosen International as your location.
What do you want to do?