The MultiMACS Cell24 Separator Plus is a semi-automated cell separator that enables magnetic cell separations based on MACS® MicroBeads and MACS Columns. It is the first step to automated cell separation and allows for parallel multisample magnetic cell isolation using MACS Technology. Whether you are dealing with high sample numbers, large sample volumes, or individual samples, the convenient design of the MultiMACS Cell24 Separator Plus provides versatility to upscale and downscale depending on your requirements. The instrument is designed for isolation of virtually any cell type from any source, giving reliable and standardized results. It is compatible with many downstream applications, such as flow cytometry, cell-culture assays, or molecular analysis.

Benefits

Speed

Simultaneous cell isolation from large sample volumes, such as buffy coats or Leukopaks®, and high sample numbers, like mouse samples.

Scalability

Parallel processing of one to 24 samples to fit every workflow, including few or small samples and high-throughput applications with the MultiMACS X.

Ease of use

Standard programs for all MACS Cell Separation strategies with step by step instructions that guide you through the separation protocols.

Versatility

Compatible with LS, LD, and Whole Blood columns and Multi-24 Column Blocks for high purity separations by positive selection, depletion, or untouched isolation of practically any target cell.

Features & specifications

MultiMACS Cell24

MultiMACS Magnet and MultiMACS Column Holder

Enable cell separation with up to 12 single columns and the Multi-24 Column Blocks.

Touchscreen

Easy to operate touchscreen interface to guide you through the protocol step by step.

Elution Chamber with Lids

Magnetically labeled cells can be collected in Deep Well Plates or 5 mL tubes.

MACS Elution Station

Vacuum impulse for elution of your labeled cell fraction.

Single-Column Adapter

Parallel isolation of up to 12 samples with LS, LD and Whole Blood Columns.

MultiMACS 5 mL Tube Rack

Collection of your cells in 5 mL tubes.

Multi-24 Column Block and 24-well Deep Well Plate

Isolation of up to 24 samples in parallel and cell collection in plate reservoirs.

1 2 3 4 5 6 7

MultiMACS Magnet and MultiMACS Column Holder

Enable cell separation with up to 12 single columns and the Multi-24 Column Blocks.

Touchscreen

Easy to operate touchscreen interface to guide you through the protocol step by step.

Elution Chamber with Lids

Magnetically labeled cells can be collected in Deep Well Plates or 5 mL tubes.

MACS Elution Station

Vacuum impulse for elution of your labeled cell fraction.

Single-Column Adapter

Parallel isolation of up to 12 samples with LS, LD and Whole Blood Columns.

MultiMACS 5 mL Tube Rack

Collection of your cells in 5 mL tubes.

Multi-24 Column Block and 24-well Deep Well Plate

Isolation of up to 24 samples in parallel and cell collection in plate reservoirs.

MultiMACS Cell24
  • Guito, J. C. et al. (2021) Asymptomatic Infection of Marburg Virus Reservoir Bats Is Explained by a Strategy of Immunoprotective Disease Tolerance. Curr. Biol. 31(2): 257-270
  • Pascual-García M. et al. (2019)
    LIF regulates CXCL9 in tumor-associated macrophages and prevents CD8
    +
    T cell tumorinfiltration impairing anti-PD1 therapy.
    Nat Commun. 10: 2416
  • Ferrara, F. et al. (2018)
    Rapid purification of billions of circulating CD19
    +
    B cells directly from leukophoresis samples.
    N Biotechnol. 46: 14-21
  • Crombie, D. et al. (2017) Development of a Modular Automated System for Maintenance and Differentiation of Adherent Human Pluripotent Stem Cells. SLAS Discov. 2(8): 1016-1025
  • Takeshi, I. et al. (2016) Regulation of CD44 expression and focal adhesion by Golgi phosphatidylinositol 4-phosphate in breast cancer. Cancer Sci. 107(7): 981-990
  • Paul, D. et al. (2015) Automated, high-throughput derivation, characterization and differentiation of induced pluripotent stem cells. Nat. Methods
  • Hubner, N. et al. (2011) Extracting gene function from protein–protein interactions using Quantitative BAC InteraCtomics (QUBIC). Methods 53(4): 453-459
  • Qing-Fang, L. et al. (2008) Sphingosine 1-phosphate induces Mcl-1 upregulation and protects multiple myeloma cells against apoptosis. Biochem. Biophys. Res. Commun. 371(1): 159-162

Applications

Support

We help you get the best results

  • Our technical support team is available to assist you throughout your projects including providing advice on experimental design, sample preparation, troubleshooting, and service options for your instrument.
  • You can access a collection of FAQs and technical documents, including datasheets, protocols, and manuals.
  • Visit MACS Academy to see all hands-on training, online courses, and live webinars that you can take part in.
  • Protect your instrument with a comprehensive service contract.

MultiMACS Cell24 Separator Plus

Parallel cell separation of large sample numbers and high sample volumes

Request a quote Schedule a demo

Related products for
MultiMACS™ Cell24 Separator Plus

6 products available | view all