Jak1 Antibody, anti-human/mouse/rat, REAfinity™
Synonyms: Tyrosine-protein kinase JAK1, Janus kinase 1, JAK-1
RECOMBINANT EXTENDED VALIDATION
Bioz Star93/100 Bioz rating
5 Citations
Clone:
REA700 | 413104
Type of antibody:
Primary antibodies, Recombinant antibodies
Isotype:
recombinant human IgG1
Applications:
ICFC, MICS, IF, IHC Glossary
External link icon
Quality Assurance Certified ProductSatisfaction
guaranteed
more »
Select a conjugate:
Select a size:
Other sizes

Related products for Jak1 Antibody, anti-human/mouse/rat, REAfinity™

Intracellular flow cytometry applications
APC
PE
Vio B515
Recommended dilution:
1:50
Remark:
The antibody is suited for staining of formaldehyde-fixed cells.
Data source:
Miltenyi Biotec
Conjugate:
APC
Used products:
130-110-608, 130-110-550
Description:
Human Jurkat cells were fixed and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Jak1 antibodies or the corresponding REA Control (I) antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Application image
Intracellular flow cytometry applications
Vio B515
Description:
Human Jurkat cells were fixed and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Jak1 antibodies or the corresponding REA Control (I) antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.
MICS (MACSima Imaging Cyclic Staining) applications
APC
PE
Fixation:
FFPE
Species tested:
human
Recommended dilution:
1:50
Data source:
Miltenyi Biotec
Compatible applications:
IF, IHC
Conjugate:
APC
Used products:
130-110-608, 130-110-550
Testing grade:
Product data and images for Jak1 Antibody, anti-human/mouse/rat, REAfinity™
Figure 1

PC-12 cells were fixed and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Jak1 antibodies or the corresponding REA Control antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Figure 2

NIH 3T3 cells were fixed and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Jak1 antibodies or the corresponding REA Control antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Figure 3

Human Jurkat cells were fixed and permeabilized using the Cell Signaling Buffer Set A. Cells were then stained with Anti-Jak1 antibodies or the corresponding REA Control (I) antibodies and analyzed by flow cytometry using the MACSQuant® Analyzer. Cell debris were excluded from the analysis based on scatter signals.

Extended validation for Jak1 Antibody, anti-human/mouse/rat, REAfinity™
Specificity
Epitope competition assay

In order to compare the epitope specificity of an antibody, the clone being used is compared with other known clones recognizing the same antigen in a competition assay.

Other clones
Overlap in epitope recognition with REA700
413104
high

Cells were incubated with an excess of purified unconjugated Jak1 (REA700) antibody followed by staining with fluorochrome-conjugated antibodies from other known clones targeting the same antigen. Fluorescence intensity was then used to assess epitope overlap: a minimal or absent signal indicated high epitope overlap, an intermediate signal suggested partial overlap, and a strong signal reflected low overlap.

Specifications for Jak1 Antibody, anti-human/mouse/rat, REAfinity™
Overview

Clone REA700 recognizes the human, mouse, and rat Jak1 antigen, also known as tyrosine-protein kinase JAK1 or janus kinase 1. Jak1 is a widely expressed membrane-associated phosphoprotein characterized by the presence of a second phosphotransferase-related domain immediately N terminal to the PTK domain. Jak1 is involved in the IFN-α/β/γ signal pathway and activates transcription factors of the STAT family by phosphorylating critical tyrosine regulatory sites.

Additional information: Clone REA700 displays negligible binding to Fc receptors

Alternative names

Tyrosine-protein kinase JAK1, Janus kinase 1, JAK-1

Detailed product information

Technical specifications

Clone
REA700
Clonality
monoclonal
Isotype
recombinant human IgG1
Isotype control
REA Control Antibody (I), human IgG1
Host
human cell line
Type of antibody
Primary antibodies, Recombinant antibodies
Species reactivity
human, mouse, rat
Antigen
Jak1
Molecular mass of antigen [kDa]
133, same molecular weight for human and mouse/rat
Distribution of antigen
ubiquitous
Entrez Gene ID
RRID
AB_2652545, AB_2652547, AB_2652546, AB_2652544

Recombinant antibodies at Miltenyi Biotec

As an innovation-powered company with a commitment to quality and excellence, Miltenyi Biotec applies cutting-edge methods to discover and develop newer and better antibodies to satisfy both market demand and regulatory requirements.

The Miltenyi way of generating best-in-class antibodies and antibody conjugates

At Miltenyi Biotec, we opt for recombinant antibodies, which enable sequence verification and optimization for lot-to-lot consistency, making them superior to hybridoma-based antibodies.

Infusing our unique expertise

Recombinants are the result of combining genetic material from different immunized animals, and using display technologies to screen in-house antibody libraries for the best antibodies. Additional analyses on existing hybridoma-based antibodies can also give rise to sequences contributing to novel recombinants.

Maximizing value for your research

By further re-engineering these antibody sequences, we can precisely control their properties to achieve the following benefits:

reduce undesirable binding to Fc gamma receptors,

  • eliminate destabilizing amino acid motifs,
  • increase specific bonding affinity for stronger, more accurate targeting, and
  • optimize fluorochrome conjugation for brighter and clearer signals.

In a final step, by synthesizing and cloning the resulting gene sequence, we achieve an expression vector that develops a cell line, which in turn produces a special recombinant antibody.

Better science with quality antibodies

Already in 2015, 100 of the world’s leading scientists collectively called for better standards and reproducibility in antibody production, proposing recombinant antibodies to circumvent variability (Baker, M. Reproducibility crisis: Blame it on the antibodies. Nature 521, 274–276 (2015). https://doi.org/10.1038/521274a). Moreover, by applying reverse engineering, which is encouraged by the EU Directive 2016/943 r, Miltenyi Biotec acts “[i]n the interest of innovation and fostering competition…” (§16).

Resources for Jak1 Antibody, anti-human/mouse/rat, REAfinity™
Certificates

To access a Certificate of Analysis (CoA) follow the link below and enter the specific lot of your product.

Get certificate

Should you wish to request additional documentation, such as a Safety Data Sheet (SDS) in other languages than English or Swedish, an SDS-replacement document, or a Certificate of Origin (CoO), please direct your inquiry to your local technical support team.

Contact technical support

You have previously chosen International as your location.
What do you want to do?