- Always freshly prepare reagents. Failure to do so may lead to suboptimal results.
Immunostaining and clearing of mouse spleen, kidney, liver and heart for 3D imaging analysis
This application protocol describes step-by-step immunostaining and clearing of blood-rich, unperfused mouse spleen, kidney, single liver lobes and perfused heart using the MACS® Clearing Kit for downstream 3D imaging analysis. The MACS Clearing Kit enables the immunostaining and clearing of up to 20 samples.
Protocol
ON
Fixation
1 day
Permeabilization
3 days
Depigmentation
2 days dehydration and depigmentation
1 day rehydration
7 days
Immunostaining
1 day
Washing
2 days
Dehydration
1 day
Clearing
Imaging
▲ Note: In this protocol, the term "depigmentation" is used synonymously with "decolorization" and "chemical bleaching".
ON = overnight
Preparation of PFA buffer
- All steps that include paraformaldehyde (PFA) must be performed under a fume hood.
- The protocol describes the preparation of 500 mL of 4% PFA buffer. For higher or lower volumes scale the amounts of the components accordingly.
- Do not use ready-to-use PFA solutions.
- Add 20 g of PFA powder to 400 mL of PBS and stir the mixture at 60 °C under a fume hood until it is dissolved.
▲ Note: Do not boil.
▲ Note: PFA powder does not dissolve instantly. - Add 0.2–0.4 g of NaOH and continue stirring at 60 °C until the solution clears up. This may take 2–3 hours.
- Adjust the pH to 7.2–7.4 with HCl and NaOH.
- Adjust the volume to 500 mL with PBS.
- Filter the solution using a 0.22 µm filter.
- PFA buffer can be stored at 4 °C for one week. For long-term storage prepare aliquots and store at –20 °C. Avoid repeated freeze/thaw cycles.
Preparation of 1× Antibody Staining Solution
- If precipitates occur due to storage of the 10× Antibody Staining Solution at low temperature, mix well before preparation of 1× Antibody Staining Solution.
- 10× Antibody Staining Solution needs to be diluted 1:10 with sterile distilled water before use, e.g., by diluting 1 mL of 10× Antibody Staining Solution with 9 mL of sterile distilled water. Adjust the volume of
- 1× Antibody Staining Solution according to the number of samples to be cleared.
Always use freshly prepared 1× Antibody Staining Solution.
Preparation of ethanol/Tween® 20 dilutions for dehydration
- The following solutions are needed:
- Ethanol 30%/Tween® 20
- Ethanol 50%/Tween® 20
- Ethanol 70%/Tween® 20
- Ethanol 90%/Tween® 20
- Absolute (≥99.8%) ethanol/Tween® 20
- Prepare ethanol dilutions of 30%, 50%, 70%, and 90% in water. Use absolute ethanol (≥99.8%) and sterile distilled water to prepare the dilutions. Add Tween® 20 to each dilution for a final concentration of 2%.
Preparation of depigmentation solution
- Prepare depigmentation solution by dissolving 7.5 g/L carbamide peroxide in ethanol (e.g. 750 mg in 100 mL). Use absolute ethanol (≥99.8%) to prepare the solution.
▲ Note: Carbamide peroxide is hazardous. Refer to the manufacturer’s website for the safety data sheet.
▲ Note: Store at 2–8°C and protected from light. For long-term storage use a glass bottle.
Preparation of Clearing Solution from the MACS Clearing Kit
- Clearing Solution is ready-to-use, but may freeze when stored at 2–8 °C. Therefore, it is recommended to prepare aliquots and store at 2–8 °C. Take out aliquots to room temperature (20–25 °C) before proceeding to clearing of samples.
▲ Note: Use polypropylene tubes for preparation of aliquots. Other plastics might not be compatible with the Clearing Solution.
- For details on the reagents of the MACS® Clearing Kit refer to the respective data sheet.
- Use tweezers to handle the tissue.
2.1 Fixation
- Transfer samples into a tube containing PFA buffer.
▲ Note: Make sure all samples are fully immersed in PFA buffer. It is strongly recommended to perform tissue perfusion for mouse heart tissue for optimal results. - Incubate overnight at 2–8 °C.
▲ Note: It is recommended to incubate the samples under slow, continuous rotation using the MACSmix™ Tube Rotator in a PFA volume that is at least 10 times higher than the volume of the samples.
▲ Note: In order to avoid autofluorescence, do not extend the incubation time. - Wash samples 3× in PBS.
▲ Note: If not immediately processed for clearing, samples can be stored in PBS/azide buffer at 2–8 °C for several weeks.
2.2 Permeabilization
- Add 5 mL of Permeabilization Solution of the MACS Clearing Kit to a 5 mL tube.
- Transfer one sample into the tube.
▲ Note: Place only one sample in each tube to allow sufficient interaction of chemicals with the sample. - Incubate for 24 hours at room temperature (20–25 °C) under slow continuous rotation using the MACSmix Tube Rotator.
- After incubation discard Permeabilization Solution and immediately proceed to section 2.3 Depigmentation.
2.3 Depigmentation
2.3.1 Dehydration
- Perform all incubation steps protected from light.
- Discard Permeabilization Solution from 2.2 Permeabilization.
- Dehydrate sample by incubation in a series of ethanol dilutions (one sample per tube) at room temperature (20–25 °C) under slow, continuous rotation using the MACSmix Tube Rotator:
- Incubation in 30% ethanol/Tween® 20 for 4 hours
- Incubation in 50% ethanol/Tween® 20 for 4 hours
- Incubation in 70% ethanol/Tween® 20 overnight
- Incubation in 90% ethanol/Tween® 20 for 4 hours
- Incubation in absolute (≥99.8%) ethanol/Tween® 20 for 4 hours
2.3.2 Depigmentation
- Use a new tube for the depigmentation step. Transfer dehydrated sample into the tube using tweezers.
- Add 10 mL of depigmentation solution to a 50 mL tube.
- Transfer dehydrated sample pieces into the tube with depigmentation solution.
- Incubate for 16 hours overnight at 4 °C at 400 rpm using the Eppendorf Thermomixer® with Eppendorf SmartBlock™ 50 mL.
2.3.3 Rehydration
- Perform all incubation steps protected from light.
- Transfer the sample to a new 5 mL tube. Rehydration steps can be performed in the same 5 mL tube. Remove solvents as neatly as possible from the tube before adding the ethanol dilutions.
- Rehydrate sample by incubation in a series of ethanol dilutions (one sample per tube) at room temperature (20–25 °C) under slow, continuous rotation using the MACSmix Tube Rotator:
- Incubation in 90% ethanol/Tween® 20 for 2 hours
- Incubation in 70% ethanol/Tween® 20 for 2 hours
- Incubation in 50% ethanol/Tween® 20 for 2 hours
- Incubation in 30% ethanol/Tween® 20 for 2 hours
- Incubation in PBS overnight
2.4 Immunostaining and washing
- Perform all incubation steps protected from light.
- The following protocol has been optimized for fluorochrome-conjugated primary antibodies from Miltenyi Biotec. Refer to the respective Miltenyi Biotec antibody conjugate data sheet or product page for the recommended dilution. When using other antibodies refer to the manufacturer´s recommendations for antibody dilution, incubation temperature, and duration of incubation.
- Dilute the primary antibody in a final volume of 1.5 mL of 1× Antibody Staining Solution. Use a 24-well plate to prepare the dilution.
- Transfer the sample into the 24-well plate containing the antibody dilution.
- Carefully seal the plate with Parafilm® to prevent evaporation.
- Incubate sample with gentle shaking using a horizontal shaker. When using Miltenyi Biotec antibodies, incubate for 7 days at 37 °C.
- Add 5 mL of 1× Antibody Staining Solution into a 5 mL tube.
- Transfer the sample into this tube.
- Washing step 1: To remove unbound antibody, incubate sample under slow, continuous rotation for 4 hours at room temperature (20–25 °C) using the MACSmix Tube Rotator.
- Washing step 2: Discard 1× Antibody Staining Solution and repeat steps 5–7.
- Washing step 3: Perform one additional washing step with 5 mL of 1× Antibody Staining Solution. Incubate overnight at room temperature (20–25 °C) under slow, continuous rotation using the MACSmix Tube Rotator.
- If working with fluorochrome-conjugated primary antibodies, discard 1× Antibody Staining Solution and continue with section 2.5 Dehydration.
- If performing indirect staining, follow steps 12–14.
- Dilute secondary antibody in a final volume of 1.5 mL of 1× Antibody Staining Solution. Use a new 24-well plate to prepare the dilution.
▲ Note: Refer to manufacturer´s recommendations for antibody dilution. - Incubate sample in secondary antibody dilution with gentle shaking using a horizontal shaker.
▲ Note: Refer to manufacturer´s recommendations for incubation temperature and duration of incubation. - Proceed with the three washing steps above (steps 5–9).
2.5 Dehydration
- Perform all incubation steps protected from light.
- 15 mL tubes must be completely filled with the corresponding ethanol dilution.
- Always use a new tube for each dehydration step. Transfer sample into the tube using tweezers.
- Dehydrate samples by incubation in a series of ethanol dilutions in 15 mL amber tubes (one sample per tube) at room temperature (20–25 °C) under slow, continuous rotation using the MACSmix Tube Rotator.
- All 4 hour incubation steps can be extended to overnight incubation.
- Incubation in 30% ethanol/Tween® 20 for 4 hours
- Incubation in 50% ethanol/Tween® 20 for 4 hours
- Incubation in 70% ethanol/Tween® 20 overnight
- Incubation in 90% ethanol/Tween® 20 for 4 hours
- Incubation in absolute (≥99.8%) ethanol/Tween® 20 for 4 hours
- Incubation in absolute (≥99.8%) ethanol/Tween® 20 overnight
▲ Note: Replace absolute (≥99.8%) ethanol/Tween® 20 from step 5 with fresh one and incubate overnight. The tissue can then be stored long-term in absolute (≥99.8%) ethanol/Tween® 20.
2.6 Clearing
- Perform all incubation steps protected from light.
- Add 5 mL of Clearing Solution of the MACS Clearing Kit into a 5 mL amber polypropylene tube.
▲ Note: Always use polypropylene tubes to incubate sample with the Clearing Solution of the MACS Clearing Kit. - Transfer one sample into this tube.
▲ Note: Make sure the tube is completely filled with Clearing Solution. Add additional Clearing Solution if necessary to fill up the tube completely. - Incubate at room temperature (20–25 °C) under slow continuous rotation for 6 hours using the MACSmix Tube Rotator.
- Discard Clearing Solution and continue with downstream imaging analysis.
▲ Note: Cleared samples can be stored in 5 mL polypropylene or glass tubes filled with MACS® Imaging Solution at room temperature for several months.
▲ Note: Do not store cleared samples at 2–8°C, otherwise freezing artefacts and tissue damage may occur. - (Optional) If image acquisition is performed immediately after clearing, transfer cleared sample into the imaging chamber of a light sheet microscope (e.g. Ultramicroscope II or Ultramicroscope Blaze). Fill imaging chamber with MACS Imaging Solution and proceed with with image acquisition.
▲ Note: If not using UltraMicroscope Platforms, refer to the respective manual and data sheet for compatibility of instrument and sample holders.
3 products found
|
For research use only
For research use only
450 mL
For research use only
1 kit
You have previously chosen International as your location.
What do you want to do?