Products and Services - MACS Cell Separation - Manual cell separation - Columns

MACS® Cell Separation Columns at a glance

  • Tailored formats for excellent results
  • Only minimal magnetic labeling required when using columns
  • Providing an efficient and gentle cell separation environment
MACS® Columns were developed for the fast separation of any cell type labeled with MACS MicroBeads. By using columns you can rely on excellent yields and purities of cells that have been minimally labeled. In addition, cell functionality is preserved following separation and isolated cells can be immediately used in the next step of your experimental workflow. Explore the different column options below. For detailed information on the column type recommended for a certain cell separation, please refer to the data sheet provided with the particular MACS Cell Separation Reagent.

Column finder

Miltenyi Biotec offers the optimal column for all sample sizes and applications. Find the column you need with the column finder.  Go to the column finder

MS Columns

MS Columns are designed for positive selection. They can also be used for depletion of strongly magnetically labeled cells. MS Columns can be used in combination with MiniMACS™, OctoMACS™, VarioMACS™, and SuperMACS™ II Separators read more

LS Columns

LS Columns are designed for positive selection. They can also be used for the depletion of strongly magnetically labeled cells. LS Columns can be used in combination with MidiMACS™, QuadroMACS™, VarioMACS™, and SuperMACS™ II Separators. In combination with the Single-Column Adapter (SCA) LS Columns can be used with the MultiMACS Cell24 Separator Plus. read more

XS Columns

XS-Columns are designed for positive selection using the SuperMACS™ II Separator. They allow the separation of very large cell numbers in a single step. read more

Large Cell Columns

Large Cell Columns are designed for positive selection of large human or animal cells, for example megakaryocytes. Large Cell Columns can be used in combination with MiniMACS™ and OctoMACS™ Separators. read more

LD Columns

LD Columns are specially designed for stringent depletion of unwanted cells. Even weakly labeled cells are efficiently retained on the column. LD Columns can be used in combination with MidiMACS™, QuadroMACS™, VarioMACS™, and SuperMACS™ II Separators. In combination with the Single-Column Adapter (SCA) LD Columns can be used with the MultiMACS Cell24 Separator Plus. read more

CS and D Columns

CS and D Columns are designed for optimal depletion of large cell numbers.
Both types of columns can be used in combination with VarioMACS™ and SuperMACS™ II Separators.
read more

Whole Blood Column Kit

The Whole Blood Column Kit is suited for the separation of leukocyte subsets directly from human whole blood. The kit contains Whole Blood Columns and Whole Blood Column Elution Buffer for convenient positive selection of cells labeled with Whole Blood MicroBeads.
Whole Blood Columns are designed for use with MidiMACS™, QuadroMACS™, VarioMACS™, and SuperMACS™ II Separators. In combination with the Single-Column Adapter (SCA) Whole Blood Columns can be used with the MultiMACS Cell24 Separator Plus.
read more
View "10" | "50" | "100" products/page
Showing 1-10 of 10
Product Order no. Price

CS Columns

Components:
  • 25×CS Column
  • 25×3-way stopcock
  • 25×syringe (10 mL)
  • 25×flow resistor (20G)
  • 25×flow resistor (21G)
  • 25×flow resistor (22G)
  • 25×flow resistor (23G)
 
130-041-305 $475.00

D Columns

Components:
  • 5×D Column
  • 5×flow resistor (20G)
  • 5×flow resistor (21G)
  • 5×flow resistor (22G)
  • 5×3-way stopcock
 
130-041-201 $555.00

Large Cell Columns

Components:
  • 25×Large Cell Column
  • 25×flow resistor (23G)
 
130-042-202 $250.00

LD Columns

Content: 25 columns
 
130-042-901 $360.00

LS Columns

Content: 25 columns
 
130-042-401 $360.00

LS Columns plus tubes

Components:
  • LS Columns (130-042-401)
  • 13 mL Tubes (3×25)
 
130-041-306 $400.00

MS Columns

Content: 25 columns
 
130-042-201 $220.00

MS Columns plus tubes

Components:
  • MS Columns (130-042-201)
  • 5 mL Tubes (3×25)
 
130-041-301 $250.00

Whole Blood Column Kit

Components:
  • 10×Whole Blood Column
  • Whole Blood Column Elution Buffer
 
130-093-545 $105.00

XS Columns

Components:
  • 5×XS Column
  • 5×3-way stopcock
  • 5×syringe (20 mL)
  • 5×syringe (50 mL)
  • 5×tube with flow resistor
 
130-041-202 $555.00
View "10" | "50" | "100" products/page
Showing 1-10 of 10

Customer login

Go

Forgot password?
Register for account

0 Shopping cart

Contact

Miltenyi Biotec Inc.
Phone: +1 800 FOR MACS
Fax:+1 877 591 1060
macs@miltenyibiotec.com
Contact overview

Product finder

Antibody panel builder

Toolbox

Loading...

$name
Get rewarded for the reagents you love

Get rewarded for reagents

Change country

Please select your country to continue