| PolySon™ ultrasound contrast agents |
|
| Description |
PolySon™ H and PolySon™ L consist of micrometer-sized air-filled polymeric particles specifically formulated for pre-clinical ultrasound imaging. Due to large differences in their density and compressibility compared to tissue or plasma, dispersed PolySon microbubbles are highly echogenic. Upon intravenous injection, the intact microbubbles circulate in the blood pool for up to 10 minutes and are taken up by the reticuloendothelial system (RES), particularly in the liver and spleen. |
| Applications |
PolySon can be applied in various ultrasound imaging techniques, such as harmonic, subharmonic and B-mode imaging. Moreover, it is particularly suited for stimulated acoustic emission (SAE) imaging (bubble rupture) using a relatively low-energy ultrasound beam (low mechanical index – PolySon L) or using a relatively high-energy ultrasound beam (high mechanical index – PolySon H).
PolySon is indicated for use in ultrasound imaging of small animals, for example mice, to facilitate evaluation of perfusion patterns and visualization of the liver and spleen. Examples include sensitive particle acoustic quantification (SPAQ) studies, imaging of liver tumors and perfusion studies of the cardiovascular system, renal system, or intratumoral vessels. |
| Disclaimer |
For laboratory and animal research use only. Warning: Not for human or animal therapeutic or diagnostic use. Make sure to comply with all laws and regulations governing research on animals. |
| |
| Figure 1 |
| Schematic diagram of a polymeric microbubble. |
 |
|
|
|
 |
| Favorites / Prices |
Request prices or add products to your favorite list.
|
| Details |
|
| Products |
| PolySon H |
- 5 injections (1) Components - 1 vial Download datasheet 130-095-152
|
- 25 injections (1) Components - 5 vials Download datasheet 130-095-153
|
| PolySon L |
- 5 injections (2) Components - 1 vial Download datasheet 130-095-150
|
- 25 injections (2) Components - 5 vials Download datasheet 130-095-151
|
| (1) After reconstitution one vial contains 850 μL of imaging agent, sufficient for 5 injections of the recommended volume of 100 μL (for a 20–30 g mouse). |
| (2) One vial contains 850 μL of imaging agent, sufficient for 5 injections of the recommended volume of 100 μL (for a 20–30 g mouse). |
|
| References |
| 1. Reinhardt, M. et al. (2005) Invest. Radiol. 40: 2–7. |
| 2. Tiemann, K. et al. (2000) Ultrasound Med. Biol. 26: 1161–1167. |
| 3. Hauff, P. et al. (2004) Radiology 231: 667–673. |
|
|
|
© 1999 - 2012 Miltenyi Biotec ¦ Terms & conditions ¦ Legal notes
|